Ϻ ν緹̼ 
 
Lab.Gruppen   پ  ȯ濡  ŷڸ   ִ      ް ֽϴ. C10:4X  ̿  Ƽ ״ ġ ȯ濡   ֵ 谡 Ǿϴ.  ä ؾ ϴ ȯ濡 ۷  ȿ   ,   ϴ C10:4X پ ɰ   ų  ִ ŸƮ մϴ.  Ʈ,  , , ȣ    پ  ϱ   ý   , , ȸ  پ ġ ȯ濡 ΰ ý  մϴ. 
 
  äο ɿ   ġ ʰ ý   ֵ Lab.gruppen Ͼ ο ´ Ͽϴ. Ư㸦 ȹ D  ȸ    ´ ִ  90 %  ȿ Ǹ       ϰ ˴ϴ. ο Ϲ Ī Ŀ ö̴ PFC Ͽ   ȿ ƴ϶ 100 ~ 240 V / 50 ~ 60 Hz п   ϸ, Ϲ IEC ڵ带 մϴ. 
 
C10:4X  äο Ư ȯ   ¿    Ư  ԵǾ ֽϴ. Է  2 ä    ְ, 35 Hz н    ֽϴ.  ä  긮 ϸ, Lab.gruppen    ũ (VPL)   äο Ǿ  äο  Ͽ     ϰ ˴ϴ. 
 
Ʈ   Ʈѿ پ  ϴ C 10:4X NomadLink Ʈũ Ʈ Ǹ ɼ   ִ NLB 60E NomadLink 긮  Ʈũ Ʈѷ PC ̴ Ʈ   ֽϴ. NomadLink ̽ Ʈ Ʈ Ͽ  Ķ   ִ μ Ʈũ Ʈ  Ŀ   On/Off   ְ ä Ʈ  ֽϴ. ̿ ϰ GPIO ϰ Ǹ  Ƽ  ý ؼ   Ʈ  ְ ˴ϴ. 
 
Ⱓ   ϵ ϱ ؼ C10:4X  ֿ켱 ϴ  ȸ ΰ ϸ  Ͽϴ. ȣ   ȸδ ʰ , DC , ,  ƴ VHF( )  ܶ   ϰ ̸ մϴ. ߰ Ʈ ŸƮ  PSU   ȣ  Ͽ ȸΰ ܵǰų  ǻ ܶǴ  ý ȣ  ֵ Ͽϴ.
| TECHNICAL DATA | 
 | 
 | 
|  General | 
 | 
|  Number of channels | 
4 | 
|  Peak total output all channels driven | 
1000 W | 
|  Peak output voltage per channel  | 
100 V / 70 Vrms | 
|  Max. output current per channel | 
9 Arms | 
|  Max. Output Power | 
16 ohms 8 ohms 4 ohms  2 ohms  HI-Z | 
|  Per ch. (all ch.s driven) | 
   250 W      250 W     250 W    125 W    250W70Vrms/100Vpeak) | 
|  Bridged per ch. | 
   500 W      500 W     250 W    n.r   500 W (140Vrms/200V peak) | 
|  Performance with Gain: 35 dB and VPL: 100 V | 
 | 
|  THD 20 Hz - 20 kHz for 1 W | 
<0.1% | 
|  THD at 1 kHz and 1 dB below clipping  | 
<0.05% | 
|  Signal To Noise Ratio  | 
>112 dBA | 
|  Channel separation (Crosstalk) at 1 kHz  | 
>70 dB | 
|  Frequency response (1 W into 8 ohms) +0/-3 dB | 
2.3 Hz - 56 kHz | 
|  Input impedance  | 
20 kOhm | 
| Input Common Mode Rejection, CMR | 
50 dB | 
|  Output impedance @ 100 Hz  | 
48 mOhm | 
 | 
 | 
|  Voltage Peak Limiter (VPL), max. peak output | 
 | 
|  VPL, selectable per ch. | 
100, 63, 45, 32 V | 
|  VPL, selectable when bridged  | 
200, 126, 90, 64 V | 
|  Voltage Peak Limiter mode (per ch.) | 
Hard / Soft | 
|  Gain and Level | 
 | 
 Amplifier gain selectable (all channels) 1) – rear-panel switches | 
29, 32, 35, 39 dB | 
|  Default gain  | 
32 dB | 
|  Level adjustment (per  ch.) | 
Front-panel potentiometer, 21 position detented from -inf to 0 dB, hidden behind security panel/dust filter grille | 
|  Connectors and Switches | 
 | 
|  Input connectors (per ch.) | 
3-pin Phoenix, electronically balanced | 
|  Output connectors (per ch.)  | 
Barrier strip 2-pole screw terminals | 
|  Output bridge mode  | 
A+B and/or C+D, inputs A and C are signal source | 
|  High pass filter | 
Fixed at 35 Hz, switchable per channe | 
|  NomadLink network | 
Yes, depending on presence of output signal | 
|  Cooling | 
Two fans, front-to-rear airflow, temperature controlled speed | 
|  Intelligent fans (on/off) | 
Yes, depending on presence of output signal | 
|  Power on/off and Remote enable on/off | 
Individual switches on front-panel | 
|  General Purpose Outputs (GPO) | 
Contact Closure types, 2-pole Phoenix | 
|  General Purpose Inputs (GPI) | 
Contact Closure types, 2-pole Phoenix | 
|  Front-panel indicators: | 
 | 
|  Common | 
NomadLink Network; Power Average Limiter (PAL) 2); Power on | 
|  Per channel | 
Signal present / High-impedance; Voltage Peak Limiter (VPL); Current Peak Limiter (CPL): Very High Frequency (VHF); High temperature; Fault; Mute | 
|  Power | 
 | 
| Operating voltage, 230 V / 115 V nominal | 
100-240 V | 
| Minimum power-up voltage, 230 V / 115 V | 
90 V | 
| Power Average Limiter (PAL) 2) | 
Yes | 
| Soft start / Inrush current draw | 
Yes / max. 5 A | 
| Mains connector | 
IEC Inlet / NEMA 5-15P | 
|  Dimensions (W/H/D) | 
W: 483 mm (19), H: 88 mm (2 U), D: 343 mm (13.5) | 
|  Weight | 
8.5 kg (18.75 lbs.) | 
|  Finish | 
Black painted steel chassis with gray painted steel front | 
|  Approvals | 
CE, ANSI/UL 60065 (ETL), CSA C22.2 NO. 60065, FCC | 
Note 1): Automatic -6 dB gain compensation when bridging channels. Ch.s A+B and/or C+D, can be bridged individually.
Note 2): PAL can reduce the maximum output power to keep the power supply operating safely, and/or to prevent excessive current draw tripping the mains breaker.
Refer to Operation Manual.
Note 3): For sine waves, peak voltage output values translate to Vrms with the formula V/1.41 = Vrms. E.g. 100 V peak equals app. 70 Vrms.
Hence, outputs can be set for high-impedance loads without requiring a transformer.
All specifications are subject to change without notice.