TECHNICAL DATA |
|
|
General |
|
Number of channels |
8 |
Peak total output all channels driven |
1000 W |
Peak output voltage per channel |
100 V / 70 Vrms |
Max. output current per channel |
5.6 Arms |
Max. Output Power |
16 ohms 8 ohms 4 ohms 2 ohms HI-Z |
Per ch. (all ch.s driven) |
125 W 125 W 125 W 60 W 125W70Vrms/100Vpeak) |
Bridged per ch. |
250 W 250 W 125 W n.r 250W(140Vrms/200V peak) |
Performance with Gain: 35 dB and VPL: 100 V |
|
THD 20 Hz - 20 kHz for 1 W |
<0.1% |
THD at 1 kHz and 1 dB below clipping |
<0.05% |
Signal To Noise Ratio |
>112 dBA |
Channel separation (Crosstalk) at 1 kHz |
>70 dB |
Frequency response (1 W into 8 ohms) +0/-3 dB |
2.3 Hz - 56 kHz |
Input impedance |
20 kOhm |
Input Common Mode Rejection, CMR |
50 dB |
Output impedance @ 100 Hz |
48 mOhm |
|
|
Voltage Peak Limiter (VPL), max. peak output |
|
VPL, selectable per ch. |
100, 63, 45, 32 V |
VPL, selectable when bridged |
200, 126, 90, 64 V |
Voltage Peak Limiter mode (per ch.) |
Hard / Soft |
Gain and Level |
|
Amplifier gain selectable (all channels) 1) – rear-panel switches |
29, 32, 35, 39 dB |
Default gain |
32 dB |
Level adjustment (per ch.) |
Front-panel potentiometer, 21 position detented from -inf to 0 dB, hidden behind security panel/dust filter grille |
Connectors and Switches |
|
Input connectors (per ch.) |
3-pin Phoenix, electronically balanced |
Output connectors (per ch.) |
Barrier strip 2-pole screw terminals |
Output bridge mode |
A+B, C+D, E+F, G+H, inputs A, C, E, G are signal source |
High pass filter |
Fixed at 35 Hz, switchable per channe |
NomadLink network |
On board, 2 x RJ45 connectors, IN and OUT |
Cooling |
Two fans, front-to-rear airflow, temperature controlled speed |
Intelligent fans (on/off) |
Yes, depending on presence of output signal |
Power on/off and Remote enable on/off |
Individual switches on front-panel |
General Purpose Outputs (GPO) |
Contact Closure types, 2-pole Phoenix |
General Purpose Inputs (GPI) |
Contact Closure types, 2-pole Phoenix |
Front-panel indicators: |
|
Common |
NomadLink Network; Power Average Limiter (PAL) 2); Power on |
Per channel |
Signal present / High-impedance; Voltage Peak Limiter (VPL); Current Peak Limiter (CPL): Very High Frequency (VHF); High temperature; Fault; Mute |
Power |
|
Operating voltage, 230 V / 115 V nominal |
100-240 V |
Minimum power-up voltage, 230 V / 115 V |
90 V |
Power Average Limiter (PAL) 2) |
Yes |
Soft start / Inrush current draw |
Yes / max. 5 A |
Mains connector |
IEC Inlet / NEMA 5-15P |
Dimensions (W/H/D) |
W: 483 mm (19), H: 88 mm (2 U), D: 343 mm (13.5) |
Weight |
8.5 kg (18.75 lbs.) |
Finish |
Black painted steel chassis with gray painted steel front |
Approvals |
CE, ANSI/UL 60065 (ETL), CSA C22.2 NO. 60065, FCC |
Note 1): Automatic -6 dB gain compensation when bridging channels. Ch.s A+B and/or C+D, can be bridged individually.
Note 2): PAL can reduce the maximum output power to keep the power supply operating safely, and/or to prevent excessive current draw tripping the mains breaker.
Refer to Operation Manual.
Note 3): For sine waves, peak voltage output values translate to Vrms with the formula V/1.41 = Vrms. E.g. 100 V peak equals app. 70 Vrms.
Hence, outputs can be set for high-impedance loads without requiring a transformer.
All specifications are subject to change without notice.